Literature summary for 3.4.17.16 extracted from

  • Huang, X.D.; Tong, W.W.; Fan, X.L.; Li, Z.H.
    Application of HPLC-ESI-ITMS in the quality control of carboxyterminal sequence confirmation for the recombinant DNA product Hirudin Variant 3 (2007), J. Pharm. Biomed. Anal., 43, 533-539.
    View publication on PubMed

Organism

Organism UniProt Comment Textmining
Penicillium janthinellum
-
-
-

Substrates and Products (Substrate)

Substrates Comment Substrates Organism Products Comment (Products) Rev. Reac.
hirudin variant 3 + H2O HPLC-ESI-ITMS is used as atool to confirm the C-terminal sequence of HV3, the degradation of the C-terminal of HV3 is studied using carboxypeptidase P und Y Penicillium janthinellum ?
-
?

Synonyms

Synonyms Comment Organism
Carboxypeptidase P
-
Penicillium janthinellum
CPP
-
Penicillium janthinellum
membrane Pro-Xaa carboxypeptidase
-